Automatic Transfer Switch Controller. Build your own change-over panel

$ 55.95

Availability: 59 in stock
  • Return shipping will be paid by: Buyer
  • Item must be returned within: 30 Days
  • Condition: New
  • Brand: GENCONTROL
  • Model: ATS105SP
  • Refund will be given as: Money Back
  • Make: GENCONTROL
  • UPC: Does not apply
  • Restocking Fee: No
  • All returns accepted: Returns Accepted
  • MPN: ATS105SP-12V

    Description

    Automatic Transfer Switch Controller. Build your own change-over panel
    This product data sheet is originally written in English.
    Automatic Transfer Switch Control Module
    Description
    The configurable Automatic Transfer Switch Model ATS105SP allows many of the industry’s demanding specifications to be achieved. The ATS105SP is used to start a generator on a mains outage, sending a signal to the Auto Start Enabled Generator and transfers the load when engine’s operating criteria has been met. The engine's warm-up time before accepting load and cool-down time after relieving load can be set directly on the module (by linking pins 5,6,7,8 and battery negative pins 9,10,11,12).The ATS105SP allows working on 3 phase and single phase mains/generator supply. Each phase is monitored individually.
    How it works
    Under normal circumstances when mains power is available, National Grid power supply runs through the Automatic Transfer Switch (ATS) contactors* and connects to your distribution board. When mains power fails, the ATS will pause for a 25 sec. period to ensure you haven’t had a power spike. ATS will then initiate a generator start signal (by closing terminals 3 and 4), warm up the generator within preset time set by internal programmable timer* (see table A in PDF manual below) and then connect the generator power supply to your home or business premises. Upon mains power being restored and stays healthy for more than 25 sec. the reverse happens and the controller automatically transfers load from the generator power back to mains shutting down the generator after a cool-down period (cool-down period = warm-up period) and restoring it to standby mode. The ATS105SP series modules have been designed for front panel mounting. The module is fitted into the cut-out (68X68mm) with the fixing clips removed. These are then fitted from the rear.
    Download PDF Manual:
    https://drive.google.com/open?id=1M-b-ichadCH3eQO3OuG6AR-xtgVAv0ss
    Wiring Diagrams
    Table "A"
    Internal Programmable Time Delay Settings
    T1
    Pin 8
    T2
    Pin 7
    T3
    Pin 6
    T4
    Pin 5
    Delay Time
    (sec)



    8
    15

    25



    32

    50




    55


    70

    95


    120


    140



    165

    190


    210


    235



    260


    280
    Example: to set up
    140
    sec. (warm-up/cool-down) delay time link pin 6 & pin 7 to the battery negative (pins 9,10,11,12 are all negative).
    Pins 8 & 5 are left unused.
    "

    " Terminal
    connected to batt. –ve
    Specification
    DC Supply: 12VDC (or 24VDC)
    Max. Operating Current: 80 mA at 12V
    Max. Standby Current: 10 mA at 12 V
    Alternator/Mains Input Range: 100 - 300 V AC
    Frequencies supported: 50Hz and 60Hz
    Mains/Generator Contactor Relay output:10 Amp at 250V AC
    Generator Start Volt Free Relay output: 2 Amp. At 28V DC
    Dimensions: 72 X 72 X 60mm
    Operating Temperature Range: -30 to +70°C
    2 X side clamps for secure panel fixing included.
    What is in the package:
    1 X ATS105SP control module
    2 X side clamps
    1 X Manual:
    https://drive.google.com/open?id=1M-b-ichadCH3eQO3OuG6AR-xtgVAv0ss
    *Important note:
    Contactors (external relays) and other related items (fuses, cables, wires, interlocks etc) not included.
    You are purchasing ATS105SP control module only.
    We have a wide range of contactors (any size, 3 and 4 pole) available. Please send us your inquiry.
    Under normal circumstances when mains power is available, National Grid power supply runs through the Automatic Transfer Switch (ATS) contactors* and connects to your distribution board. When mains power fails, the ATS will pause for a 25 sec. period to ensure you haven’t had a power spike. ATS will then initiate a generator start signal (by closing terminals 3 and 4), warm up the generator within preset time set by internal programmable timer* (see table A in PDF manual below) and then connect the generator power supply to your home or business premises. Upon mains power being restored and stays healthy for more than 25 sec. the reverse happens and the controller automatically transfers load from the generator power back to mains shutting down the generator after a cool-down period (cool-
    MPN
    ATS105SP-12V
    Model
    ATS105SP
    Brand
    GENCONTROL
    Make
    GENCONTROL